Prolux delivers a comprehensive range of engineered fire and blast protection solutions for oil & gas, petrochemical, power generation, and defence facilities — including blast-resistant barriers, transformer fire/explosion barriers, free-standing and hydrocarbon fire barriers, generator room fire walls, dual-rated fire/blast barriers, jet fire barriers, protection screens, blast & fire-resistant doors and windows, and blast-relief vents. All products are custom-engineered, modular for rapid deployment, and certified to international standards (API, ASCE, UFC, EN, NFPA, ISO, IMO SOLAS) to safeguard personnel, equipment, and critical infrastructure.
ASSET INTEGRITY PROTECTION
Fire & Blast Resistant Barriers
Personnel & Equipment Protection from Fire & Blast Overpressure Events
Prolux supplies engineered blast resistant barriers designed to protect personnel, equipment and critical assets from blast overpressure events in petrochemical plants, oil & gas facilities and defence installations. Our barriers are designed to internationally recognised blast resistance standards and are available in modular configurations for rapid deployment and relocation.
Key Specifications
| Design Standards | ASCE 59-11, UFC 3-340-02, EN 13123 |
| Applications | Control rooms, shelters, equipment protection bays |
| Protection Levels | Low, medium and high blast response categories |
| Construction | Steel & composite materials |
| Configuration | Modular, relocatable & permanent installations |
| Industries | Oil & gas, petrochemical, defence, power generation |
Key Features
Personnel Protection
Blast overpressure shielding
Modular Design
Rapid deployment & relocation
ASCE / UFC Standards
Internationally certified barriers
Multiple Industries
Oil & gas, petrochemical, defence
Transformer Fire & Explosion Protection Barriers
Passive Fire Protection for Power Transformers
Prolux designs and manufactures fire and explosion protection barriers for oil-filled power transformers, containing fire and blast events to protect adjacent equipment, personnel and critical infrastructure across substations and power plants.
Fire Rating: Up to 4 Hours (E240)
Blast Resistance: Up to 35 kN/m²
Internal/ External
Demountable
Light-weight
Space Saving
Moisture Resistant
Key Features
Full Containment
Blocks fire spread between transformer bays
Blast Resistant
Withstands transformer explosion overpressure
Modular Design
Fast on-site installation
Custom Engineering
Tailored to substation layout
Key Features
Independent Structure
No load on adjacent buildings
Overpressure Rated
Engineered blast load response
Rapid Deployment
Prefabricated modular panels
Site-Specific Design
Blast modelling & analysis included
Free-standing Blast Barriers
Self-Supporting Protection for High-Risk Zones
Prolux free-standing blast barriers provide independent, foundation-mounted protection against overpressure and fragmentation, designed for process areas, storage zones and perimeter protection without reliance on existing structures.
Fire: Up to 4 hrs (E240)
Blast: Up to 35 kN/m2
Freestanding Structure
Modular Construction
Lightweight Panels
No Foundation
Required
Corrosion Resistant
Free-standing Blast Barriers
Self-Supporting Protection for High-Risk Zones
Prolux free-standing blast barriers provide independent, foundation-mounted protection against overpressure and fragmentation, designed for process areas, storage zones and perimeter protection without reliance on existing structures.
Fire: Up to 4 hrs (E240)
Blast: Up to 35 kN/m2
Freestanding Structure
Modular Construction
Lightweight Panels
No Foundation
Required
Corrosion Resistant
Key Features
Independent Structure
No load on adjacent buildings
Overpressure Rated
Engineered blast load response
Rapid Deployment
Prefabricated modular panels
Site-Specific Design
Blast modelling & analysis included
Hydrocarbon Fire Barrier
High-Temperature Protection for Oil & Gas Fire Curves
Engineered for the rapid, high-temperature rise of hydrocarbon pool and jet fires, Prolux hydrocarbon fire barriers protect structural steel, vessels and critical assets across upstream, midstream and downstream facilities.
Fire Rating: Up to 4 Hours (H120)
Blast Resistance: Up to 10 kN/m²
Hydrocarbon Fire
Protection
Freestanding Design
Modular Panels
Lightweight Construction
Quick Installation
Key Features
HC Curve Rated
Rapid rise-time fire resistance
Structural Protection
Preserves steel integrity under fire
Weatherproof Cladding
Marine & offshore grade finishes
Low Maintenance
Corrosion-resistant construction
Key Features
Fire Rating
1–4 hours (EN / ASTM / UL rated)
Wall Types
Solid partition, louvred acoustic-fire rated
Construction
Fire-rated board, composite or masonry-clad steel
Acoustic Performance
Optional attenuation up to 35dB
Penetrations
Fire-stopped cable & ducting penetrations
Standards
NFPA 37, IBC, local civil defence codes
Generator Room Fire Walls
Compartmentation for Emergency & Standby Power
Prolux fire walls create certified fire-rated compartments around generator rooms, isolating fuel and electrical fire risk from surrounding areas and maintaining emergency power availability during a fire event.
Fire: Up to 4 hrs (E240)
Blast: Up to 35 kN/m2
Integrated Ventilation
Structural Steel Support
Demountable Panels
Lightweight Design
Fast Installation
Generator Room Fire Walls
Compartmentation for Emergency & Standby Power
Prolux fire walls create certified fire-rated compartments around generator rooms, isolating fuel and electrical fire risk from surrounding areas and maintaining emergency power availability during a fire event.
Fire: Up to 4 hrs (E240)
Blast: Up to 35 kN/m2
Integrated Ventilation
Structural Steel Support
Demountable Panels
Lightweight Design
Fast Installation
Key Features
Fire Rating
1–4 hours (EN / ASTM / UL rated)
Wall Types
Solid partition, louvred acoustic-fire rated
Construction
Fire-rated board, composite or masonry-clad steel
Acoustic Performance
Optional attenuation up to 35dB
Penetrations
Fire-stopped cable & ducting penetrations
Standards
NFPA 37, IBC, local civil defence codes
Integrity and Insulated Fire & Blast Barriers
Dual-Rated Protection Against Fire and Explosion
Combining fire integrity with thermal insulation and blast resistance, Prolux dual-rated barriers protect personnel escape routes, control rooms and critical equipment from combined fire and explosion hazards in a single certified system.
Fire: Up to 4 hrs (EI120)
Light weight
Space Saving
No Foundation
Fast Installation
Key Features
Dual Rated
Fire integrity + insulation performance
Blast Tested
Certified fire-then-blast sequence
Personnel Protection
Safeguards escape & muster areas
Certified Assemblies
Independently tested systems
Key Features
Jet Fire Tested
ISO 22899-1 certified performance
High Heat Flux
Withstands concentrated flame impingement
Compact Footprint
Fits tight process skid layouts
Rapid Installation
Bolt-together modular panels
Jet Fire Barrier
Directional Impingement Protection
Prolux jet fire barriers are engineered and tested to withstand the intense directional heat flux of jet fires from pressurised gas or liquid releases, protecting critical assets and escape routes in high-pressure process facilities.
Jet Fire: 2 hrs
(J120)
Wind Load: 360 m/s
Singe skin
Modular construction
Corrosion protection
Export packing
Jet Fire Barrier
Directional Impingement Protection
Prolux jet fire barriers are engineered and tested to withstand the intense directional heat flux of jet fires from pressurised gas or liquid releases, protecting critical assets and escape routes in high-pressure process facilities.
Jet Fire: 2 hrs
(J120)
Wind Load: 360 m/s
Singe skin
Modular construction
Corrosion protection
Export packing
Key Features
Jet Fire Tested
ISO 22899-1 certified performance
High Heat Flux
Withstands concentrated flame impingement
Compact Footprint
Fits tight process skid layouts
Rapid Installation
Bolt-together modular panels
Protection Screens/Enclosures
Modular Screening for Equipment & Personnel Safety
Prolux protection screens and enclosures provide flexible fire, blast and fragmentation shielding around valves, pumps, control equipment and work areas, combining safety performance with ease of access and maintenance.
Fire Rating: Up to 4 Hrs (E240)
Blast Resistance: Up to 35 k
Demountable
Light Foundation
Light-weight
Space Saving
Key Features
Modular Panels
Configurable to any equipment layout
Easy Access
Hinged & removable maintenance panels
Multi-Hazard
Fire, blast & fragment protection combined
Custom Fabrication
Engineered to exact site dimensions
Key Specifications
| Product Range | Blast doors, fire doors (A60), ballistic doors, blast windows, blast panels |
| Blast Standards | EN 13123 / EN 13124, ASTM F2927, ISO 16933 |
| Fire Standards | A60 fire rating (IMO SOLAS compliant) |
| Blast Levels | Low, medium & high blast response categories |
| Frame Materials | Steel, aluminium & composite frames |
| Applications | Control rooms, shelters, E-houses, offshore platforms |
Key Features
Full Door Range
Blast, fire (A60) & ballistic options
Blast Windows
Single & multi-glazed blast resistant
EN 13123 Certified
Internationally recognised testing
Offshore Ready
IMO SOLAS A60 fire rated
Blast & Fire-Resistant Doors & Windows
Prolux supplies blast resistant and fire-rated door and window assemblies for control rooms, blast shelters, E-houses and high-risk industrial buildings. Our product range includes blast resistant doors (single & double leaf), fire resistant doors (A60 rated), ballistic doors, blast resistant windows and blast panels
Blast & Fire-Resistant Doors & Windows
Prolux supplies blast resistant and fire-rated door and window assemblies for control rooms, blast shelters, E-houses and high-risk industrial buildings. Our product range includes blast resistant doors (single & double leaf), fire resistant doors (A60 rated), ballistic doors, blast resistant windows and blast panels
Key Specifications
| Product Range | Blast doors, fire doors (A60), ballistic doors, blast windows, blast panels |
| Blast Standards | EN 13123 / EN 13124, ASTM F2927, ISO 16933 |
| Fire Standards | A60 fire rating (IMO SOLAS compliant) |
| Blast Levels | Low, medium & high blast response categories |
| Frame Materials | Steel, aluminium & composite frames |
| Applications | Control rooms, shelters, E-houses, offshore platforms |
Key Features
Full Door Range
Blast, fire (A60) & ballistic options
Blast Windows
Single & multi-glazed blast resistant
EN 13123 Certified
Internationally recognised testing
Offshore Ready
IMO SOLAS A60 fire rated
Blast Resistant Vents & Rupture Discs
Controlled Pressure Relief for Blast-Sensitive Structures
Prolux supplies blast resistant vents designed to mitigate blast overpressure within process buildings, control rooms and E-houses, pressure vessels, boilers. These engineered venting systems allow controlled pressure release during a blast event, protecting structural integrity and minimising secondary damage — critical for facilities in proximity to high-pressure process equipment.
Key Specifications
| Function | Pressure-relief venting to mitigate blast overpressure |
| Design Standards | NFPA 68, EN 14994 (deflagration venting), ATEX Ex II G |
| Materials | Stainless steel & aluminium, weatherproof & corrosion resistant |
| Mounting | Wall, roof flange & duct integration options |
| Applications | Control rooms, E-houses, process buildings, substations, boiler & pressure vessels |
| Custom Sizing | Designed to specific overpressure & vent area calculations |
Key Features
Pressure Relief
Controlled blast overpressure venting
Engineering Calcs
Bespoke sizing per NFPA 68 / EN 14994
Multiple Configurations
Wall, roof, Flange & duct mounting
E-Houses & Control Rooms